Ethylene Oxide Gas Sensor ETO/M-1000 Mechanical Weight g Orientation Any Housing material Polycarbonate . Rev.: Aug-20 Page 4 of 4 Phone: +41 43 311 72 00 Membrapor AG Fax: +41 43 311 72 01 Birkenweg 2 E-Mail: [email protected] CH-8304 Wallisellen Website: Switzerland Performance data recorded at 20 – 25 °C, 30 - 50% RH, 900 - 1100 mbar For further …
sensors are suitable for their own requirements. Ethylene Oxide Gas Sensor ETO/M-10 Electrical Rec. Load Resistor 10 - 33 Ω Bias (V_Sens-V_Ref) +300 mV Conformity to RoHS directive RoHS Compliance Environmental Relative Humidity Range 15 % to 90 % RH non-condensing Temperature Range -40 °C to 50 °C Pressure Range Atmospheric ± 10%
Ethylene Oxide Electrochemical Sensor EC-4ETO-100 . It detects Ethylene Oxide in level from 0-100 product is for fixed and portal applications for detection of leaks in hospital and clinical sterilization systems. Ethylene Oxide Electrochemical Sensor EC-4ETO-100 can be retrofitted easily to existing product designs.
Gas Sensors Showing all 4 results Product code: 2112B1212400 4-ETO-10 Ethylene Oxide ETO Gas Sensor, 0-10ppm 4-ETO-10 Ethylene Oxide ETO gas sensor, 0-10ppm ETO
Ethylene Oxide Gas Detectors from International Gas Detectors – We can provide a range of fixed sensors and portable gas monitors for the detection of ETO. It is important for many industries to have accurate and fast detection of ethylene oxide to avoid the gas reaching dangerous toxic levels. Discover our range of ethylene oxide gas …
PQD-6234 - Prosense PQD-6234 Gas Detector with Electrochemical sensor for Etylene Oxide (ETO) with ranges 0-20ppm or 0-100ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. OLED Display. ATEX/IECEx (Zone 1, Zone 2 or M2) approvals, optional SIL2. IP65, Optional IP66 Adaptor.
BROCHURE. Real-time Ethylene Oxide gas Monitor is the solution for the continuous monitoring of EO gas sterilization facilities. This equipment is an evolution of the DE02 model, its frame is illuminated in referential colors to inform users the values measured of EO gas within the working area, green (if the equipment is below the configured alarm threshold) or red (if it is reached or ...
Electrochemical Ethylene Oxide Sensor EC-4ETO-10 . EC-4ETO-10 is Ethylene Oxide Sensor which detects Ethylene Oxide in level from 0-10 product is for fixed and portal applications for detection of leaks in hospital and clinical sterilization systems. Ethylene Oxide Electrochemical Sensor EC-4ETO-10 can be retrofitted easily to existing ...
The FGD14 Ethylene Oxide gas detector is a stand-alone detector using electrochemical gas sensor technology. It has a front panel display of the gas level and an internal visual and audible alarm. The detector contains 2 control relays that can be activated via user definable alarm set points; the relay contacts can then be used to control external equipment. Communication with other equipment ...
· Abstract: The sensitivity of two commercial metal oxide (MOx) sensors to ethylene is tested at different relative humidities. One sensor (MiCS-5914) is based on tungsten oxide, the other (MQ-3) on tin oxide. Both sensors were found to be sensitive to ethylene …
An ethylene oxide calibration kit can be obtained from: SPEC AIR SPECIALTY GASES 22 Albiston Way Auburn, ME 04210phone: 1 800 292-6218The "Interscan One" calibration kit includes:A specially treated aluminum cylinder, containing 160 liters of 4 ppm ethylene oxide (balance nitrogen) span gas.
0-20 ppm Ethylene Oxide sensor with a resolution of ppm. Standard Range = 0-20 ppm. Minimum Range = 0-20 ppm . Maximum Range = 0-200 ppm. These sensors come ready to operate in any of the above preset ranges (standard, minimum, or maximum). When you connect the Sensing Module to the Gas Transmitter, you will be asked which range you would like to use. We list the standard range as …
Ethylene oxide is a strong irritant, greatly affecting the eyes, skin, and respiratory tract. It induces vomiting and nausea and can cause headaches. It can also cause depression of the central nervous system and kidney and reproductive damage. Ethylene oxide is carcinogenic, and chronic exposure has been linked to increased risk of leukemia, stomach cancer, pancreatic cancer, and non-Hodgkin lymphoma. Ethylene oxide …
Prosense PQD-6234 Gas Detector with Electrochemical sensor for Etylene Oxide (ETO) with ranges 0-20ppm or 0-100ppm. Ex-proof housing and SS316 stainless steel sensor head. 4-20mA Analog and Modbus RS485 RTU outputs, optional Relay card. OLED Display. ATEX/IECEx (Zone 1, Zone 2 or M2) approvals, optional SIL2. IP65, Optional IP66 Adaptor.
Replacing the gas sensor is a simple, 3-step process: Open the box. Connect new sensor. Return expired sensor in the pre-paid box provided by ChemDAQ. Download E-Cell Sensor Spec Sheet. SafeCide Ethylene Oxide Portable Monitor . ChemDAQ’s portable, handheld monitoring system to detect Ethylene Oxide is a rugged device built to withstand everyday use. Benefits. Fast, accurate, …
0-20 ppm Ethylene Oxide sensor with a resolution of ppm. Standard Range = 0-20 ppm. Minimum Range = 0-20 ppm. Maximum Range = 0-200 ppm. These sensors come ready to operate in any of the above preset ranges (standard, minimum, or maximum). When you connect the Sensing Module to the Gas Transmitter, you will be asked which range you would like to use. We list the standard range as the sensors range, but each sensor …
ETO - Ethylene Oxide, CAS# 75-21-8. Ethylene oxide is a colorless flammable gas at room temperature, with a faintly sweet odor; it is the simplest epoxide: a three-membered ring consisting of one oxygen atom and two carbon atoms. Detailed Description. Health Effects - Can be inhaled, and absorbed orally or through the skin. It is suggested to be the most toxic of all alkanes and can cause ...
Gas Sensors - SensAlert Ethylene Oxide Sensor 10ppm -- 452132-D-1 Supplier: Sensidyne, LP Description: Minimum Indicated Concentration .............. ppm Repeatability ......................................... ..... ± 2% of reading Accuracy * ......................................... ........ ± 2% of full scale Zero Drift ......................................... ..........
Ethylene oxide (C2H4O) is a flammable, colourless gas at temperatures above Degrees Centigrade C that smells like ether at toxic levels. We have a wide variety of ethylene oxide gas detector available. Our ethylene oxide detectors use industry leading long life sensor technology and our ground breaking Sentinel+ addressable communication. See below to learn more about ETO and our detector options. …
4-ETO-500 ETHYLENE OXIDE SENSOR 0-500PPM ETO EURO-GAS MANAGEMENT SERVICES LTD, CHURSTON HOUSE, BASCOMBE ROAD, CHURSTON FERRERS, DEVON, TQ5 0JJ, UK : +44 (0)1803 844414 Fax: +44 (0)1803 844224 [email protected] SPECIFICATION –4 SERIES Operating Principle: Electrochemical, 3-electrode cell
Description: Standard Equipment Includes: Instrument Ethylene Oxide sensor Flexible probe Instruction manual Hard carrying case Bacharach's Leakator 10 is a low maintenance combustible gas leak detection unit, small enough to be operated with
provides monitors and sensors for detecting a wide variety of toxic gases. Gas Sensing Logo. Menu. Search ... Ethylene Oxide Information. View as Grid List. 12 Items . Show. per page. Sort By. Set Descending Direction. D-16 PortaSens III Gas Detector . As low as $1, View Details. F12-is Gas Monitor . As low as $1, View Details. ATI A14/A11 Ethylene Oxide …
4-ETO-10 Ethylene Oxide ETO SS gas sensor for low range. Measuring Range: 0-10ppm ETO. Size: 4 series. Part no: 2112B1212400 (CLE-1212-400) With two year expected operating life, this low range, 4-series standard sized sensor offers …
Ethylene Oxide Ethylene Oxide. Compare BW TECHNOLOGIES. Single Gas Detector, 0 to 100 ppm Sensor Range, Audible, Vibrating, Visual Alarm Type. Item # 497A85; Mfr. Model # BWS-E-Y Catalog Page # N/A View Product Details. Web Price ...
RC Systems manufactures single and dual sensor ethylene oxide gas detectors for all industries and applications. Our combustible gas sensors reliably monitor gas levels, ensuring a safer workplace environment for your employees. Our ethylene oxide gas detectors come in several single and dual sensor models to meet your monitoring needs.
ME4-ETO ethylene oxide gas sensor is constant potential electrolysis type. Oxidation-reduction reaction with ethylene oxide gas take place inside of the sensor. The process releases electric charge and generates current. The current is in direct proportion to the concentration of ethylene oxide gas.